Why do fire inspection reports take so long?

Don’t tell anyone, but we know that a fire inspection report takes a long time. 

In an effort to explain why we’re going to lead you in a ‘behind the scenes look at the internal processes and why these reports take what seems like forever. 

When systems or devices need maintenance we often can send a repair technician to you within 24 hours (or sooner in emergencies!) Our goal is to be proactive and ensure that our systems keep you safe from harm.

What’s Included in a Fire Inspection Report? 

Clear Sightlines

One of the main elements of your fire inspection report is ensuring there are clear paths for firefighters to reach the building and for patrons to exit the building. If an emergency does happen at your commercial property, there needs to be easy access in and out of the building. This part of the inspection report will likely also include making sure your building remains up to date with fire codes. 

If there are main identifiers around the building that firefighters should be aware of (think trees or other identifying information), that also needs to be included in the fire inspection report. 

Certified Fire Extinguishers

Included in this inspection is counting the number and type of fire extinguishers throughout the building.  VFS Fire and Security services specialize in portable fire extinguishers. Per NFPA code fire extinguishers are required to be inspected and certified by a licensed fire protection contractor. There are a LOT of different types of fire extinguishers including:

  • Water Mist
  • Clean Agent
  • Foam
  • Wet Chemical
  • CO2
  • ABC Dry Chemical
  • Class A, B, C, D, and K

Inspecting all of these extinguishers takes time, which further delays that report hitting your desk. 

Emergency Lighting

Emergency illumination could mean life or death in an intense situation. Ensuring your emergency lighting is working and in the correct areas is essential to the fire prevention and safety of your building. 

We can help! 

There are so many other moving parts that are included in a fire safety inspection. The expert team at VFS Fire and Security Services has a breadth of knowledge to provide all regularly scheduled and code-mandated fire protection system inspections. The frequencies of these inspections ensure the most effective operating conditions for your building all year round and are critical to keeping current with industry and insurance codes. 

We have a diverse team of experienced fire protection professionals capable of inspecting and servicing even the most complex fire protection systems. Our advanced platforms and highly trained dispatch team allow us to manage inspections and testing from inception to execution. 

We tell you what’s due, when it’s due and why it’s due, and are constantly communicating to your team to keep you up-to-date on the latest information within your facilities. 

How frequently do you need fire inspections? Learn more about your inspection schedule in this blog post. 

What is a Public Safety DAS? NFPA, ERRCS and AHJ (Plot Twist, these letters actually mean something...)

You’re not alone if you see all the abbreviations in fire safety and think, “How the h*ll am I supposed to know what that all means?” 

DAS Explained

The amount of NFPA codes is a large number (like large as in over 300…), so we understand it’s hard to keep track of them all! Actually, are you trying to test your knowledge? Take our NFPA Fire Codes quiz and see how you do! 

Anyways, DAS stands for, “Distributed antenna system.” And no, we don’t mean the antenna for your cable TV.

The NFPA requires that “Buildings and structures that cannot support the required level of radio coverage shall be equipped with a radiating cable system or a distributed antenna system (DAS) with FCC-certified signal boosters, or both, or with a system that is otherwise approved, in order to achieve the required adequate radio coverage.” 

There are additional factors of the distributed antenna system that any commercial property owner should consider (based on NFPA standards). This might include:

  • Signal Strength
  • Isolation
  • System Radio Frequencies
  • Frequency Changes
  • Critical Areas
  • Radio Coverage

Another main component of NFPA 72 Section 24.5.2 is non-interference. 

In other words, “no amplification system capable of operating on frequencies or causing interference on frequencies assigned to the jurisdiction by the FCC shall be installed without prior coordination and approval of the authority having jurisdiction,” according to the NFPA. “The building manager/owner shall suspend and correct other equipment installations that degrade the performance of the public safety radio system or public safety radio enhancement system.” 

Let’s Talk ERRCS

So surprise, ERRCS is one in the same as DAS. An Emergency Responder Radio Communication (ERRCS) is crucial to have in commercial buildings. An ERRCS can also be identified as a Public Safety or First Responder DAS. 

It turns out all of the fire protection abbreviations can be interchangeable!

How About AHJ?

AHJ, the last acronym to understand for today’s lesson! AHJ stands for, “Authority Having Jurisdiction.” It can be a common misconception that the local fire marshall is responsible for any updates in fire safety. But this is not the case. Oftentimes there are multiple people or authorities who have jurisdiction and are responsible for a facility’s fire safety standards and practices.

The NFPA has regulations set under Code 70E

“In a commercial or industrial facility, subsequent installation of electrical equipment or modification of the distribution system is often not done under a government permit nor is this inspected by the government AHJ.” 

A good question to keep in mind listed from the NFPA is, “Does your management invite a government AHJ to inspect and approve the installation of a new subpanel, the move of a production line, the retrofit for a breakroom, the extension of a circuit, or the addition of a backup generator in your facility?”

Have more questions about these confusing acronyms? Reach out to VFS Fire & Security Services today! 

What is a Public Safety DAS? NFPA, ERRCS and AHJ (Plot Twist, these letters actually mean something...)

What is a Public Safety DAS? NFPA, ERRCS and AHJ (Plot Twist, these letters actually mean something…)

The Sprinkler is More Than an Outdated Dance pressure monitors for fire safety

It’s summertime! Time for dancing, talking, and sunshine. Maybe you’re feeling rusty with your social skills, and have a big party coming up without any amazing talking points.

Well, might as well give it a shot with different types of sprinklers! (But here’s a major hint: leave the sprinkler dance at home. You know, that cringy 80s dance move…) Here’s a rundown of different sprinkler systems for national fire prevention.

Wet Pipe System

These systems are the most popular sprinkler systems. They are extremely effective, low-cost, and low-maintenance. The system’s pipes remain filled with water. Once triggered by the heat source, water flows through the activated sprinkler to the source of the fire. These systems are extremely quick in reacting to potential fires; however, they are at risk of freezing in cold environments.

Dry Pipe System

In freezing climates, dry pipe sprinkler systems are a more suitable choice than wet pipe systems. These systems do not carry water in the piping until activation.

Instead, these pipes are filled with pressurized air and nitrogen. When the system is activated, the valve opens and water flows in when the sprinkler head is triggered.

As the water is not housed in the actual piping, you can guess that the disadvantage of dry pipe systems is that their response time is delayed. Another potential downfall to these systems is the required maintenance. Sprinkler corrosion is more prevalent in these systems, as the compressed air and oxygen create an enticing environment for corrosion.

Pre-Action System

Pre-action sprinkler systems are used to protect areas where water damage from damaged sprinklers or piping needs to be avoided. These are the middle ground between dry and wet fire protection systems.

Water is not contained in the sprinkler piping and is held back by a pre-action valve. The valve is opened when flame, heat, or smoke is detected. The detection system must detect a fire and the valve must open to initiate water to flow within the pipes. These systems are ideal for water-sensitive environments such as museums, data centers, libraries, vaults, and freezer warehouses as they carry a low risk of accidental discharge. They prevent excessive water damage and work ideally in cold conditions as the water is not held within the pipes to prevent freezing in the pipes.

Deluge System

Deluge suppression systems are typically used in special hazard installations when water must be applied to an entire area for fire protection. These systems are considered a ‘dry fire protection system’ as the piping for the system is empty and at atmospheric pressure with the sprinkler heads open. When heat or fire is detected by the system, the deluge valve releases the water, dry chemicals, inert gases, or foam.

These systems are typically used for facilities where an entire area needs to be protected immediately; rather than by a zone or specific location of the source of the heat or fire. Typical facilities that utilize deluge suppression systems are airport hangars, chemical plants, processing plants, and data storage centers. These systems are especially useful when you need to quickly flood an area to prevent a fire from growing.

The Sprinkler is More Than an Outdated DanceFoam Water Systems

Foam water systems are a type of wet sprinkler system that combines both water and a foaming agent for large-scale fire extinguishment. These specific irrigation systems are generally installed in facilities where extinguishing a fire can be more challenging than usual, due to the flammable and combustible contents housed within. 

Additional Fire Safety

Fire Pumps

Fire pumps are designed to supply water to the fire sprinkler system and its components at a higher pressure rate to effectively extinguish a potential fire. There are two main types of fire pumps: diesel and electric and they require different frequencies of maintenance and inspections due to their different components needs.

Fire Backflow

This equipment is designed to prevent water from flowing back into the main water supply. This prevents the water supply from being contaminated or polluted due to backflow. 

How to Install (VFS, Of Course!) 

At VFS Fire & Security Services we understand that your unique building needs unique fire protection systems. Our team is equipped to ensure you receive the fire protection you need to keep your building and your people safe from harm.

 

reg inspections

VFS Fire & Security Services is a company that challenges the status quo in the industry. According to Randy Nelson, CEO, “VFS has grown into a cutting edge company that focuses on innovation in an industry where the way things are done, quite frankly, has not changed much in the past 100 years. This industry has typically been slow to adopt new technology, but VFS is leading the way!”

Read more
YOUR MARINE FIRE SAFETY CHECKLIST

On October 3, 2011, a chemical plant in Waxahachie, TX erupted in flames. Clouds of toxic smoke and rivers of fire came spewing out of the plant. No one was seriously injured in what officials said was a rare mishap. But should Waxahachie fire officials have done more to anticipate this kind of accident?  Could the fire have ever been contained once it got started?

Read more